OPC Studio User's Guide and Reference
ReadMultipleValues Method (_EasyUAClient)
Example 



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA.ComTypes Namespace > _EasyUAClient Interface : ReadMultipleValues Method
Array of OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments. Array of argument objects specifying what to read from an OPC-UA server.

The value of this parameter cannot be null (Nothing in Visual Basic).

The individual elements of the parameter value cannot be null (Nothing in Visual Basic).

Reads values of multiple attributes, using array of argument objects as an input.
Reads values of multiple attributes.
Syntax
'Declaration
 
<NotNullAttribute()>
Function ReadMultipleValues( _
   ByVal readArgumentsArray As Object _
) As Object()
'Usage
 
Dim instance As _EasyUAClient
Dim readArgumentsArray As Object
Dim value() As Object
 
value = instance.ReadMultipleValues(readArgumentsArray)
[NotNull()]
object[] ReadMultipleValues( 
   object readArgumentsArray
)
[NotNull()]
array<Object^>^ ReadMultipleValues( 
   Object^ readArgumentsArray
) 

Parameters

readArgumentsArray
Array of OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments. Array of argument objects specifying what to read from an OPC-UA server.

The value of this parameter cannot be null (Nothing in Visual Basic).

The individual elements of the parameter value cannot be null (Nothing in Visual Basic).

Return Value

Array of OpcLabs.BaseLib.OperationModel.ValueResult. Returns an array of value objects. Each object contains the actual value of an attribute. The indices of elements in the output array are the same as those in the input array, readArgumentsArray.

This method never returns null (Nothing in Visual Basic).

The individual elements of the returned value are never null (Nothing in Visual Basic).

Exceptions
ExceptionDescription

A null reference (Nothing in Visual Basic) is passed to a method that does not accept it as a valid argument.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

Remarks

The status codes of attributes should be 'good'; otherwise, a OpcLabs.BaseLib.OperationModel.ValueResult.Value of that attribute is not valid, and OpcLabs.BaseLib.OperationModel.OperationResult.Exception contains a non-null exception.

The size of the input array will become the size of the output array. The element positions (indices) in the output array are the same as in the input array.

This member or type is for use from COM. It is not meant to be used from .NET or Python. Refer to the corresponding .NET member or type instead, if you are developing in .NET or Python.

This is an extension method (info: C#, VB.NET). In languages that have support for extensions methods (such as C# and VB.NET), you can use the extension method as if it were a regular method on the object that is its first parameter. In other languages (such as with Python.NET), you will call the extension as a static method, and pass it the object on which it acts as its first parameter.

Example

COM

COM

// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
// to read multiple attributes of the same node.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

#include "stdafx.h"    // Includes "QuickOpc.h", and other commonly used files
#include <atlsafe.h>
#include "ReadMultipleValues.h"

namespace _EasyUAClient
{
    void ReadMultipleValues::Main()
    {
        // Initialize the COM library
        CoInitializeEx(NULL, COINIT_MULTITHREADED);
        {
            // Instantiate the client object
            _EasyUAClientPtr ClientPtr(__uuidof(EasyUAClient));

            _UAReadArgumentsPtr ReadArguments1Ptr(_uuidof(UAReadArguments));
            ReadArguments1Ptr->EndpointDescriptor->UrlString = 
                //L"http://opcua.demo-this.com:51211/UA/SampleServer";
                L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
            ReadArguments1Ptr->NodeDescriptor->NodeId->ExpandedText = L"nsu=http://test.org/UA/Data/ ;i=10845";

            _UAReadArgumentsPtr ReadArguments2Ptr(_uuidof(UAReadArguments));
            ReadArguments2Ptr->EndpointDescriptor->UrlString = 
                //L"http://opcua.demo-this.com:51211/UA/SampleServer";
                L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
            ReadArguments2Ptr->NodeDescriptor->NodeId->ExpandedText = L"nsu=http://test.org/UA/Data/ ;i=10853";

            _UAReadArgumentsPtr ReadArguments3Ptr(_uuidof(UAReadArguments));
            ReadArguments3Ptr->EndpointDescriptor->UrlString = 
                //L"http://opcua.demo-this.com:51211/UA/SampleServer";
                L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
            ReadArguments3Ptr->NodeDescriptor->NodeId->ExpandedText = L"nsu=http://test.org/UA/Data/ ;i=10855";

            CComSafeArray<VARIANT> arguments(3);
            arguments.SetAt(0, _variant_t((IDispatch*)ReadArguments1Ptr));
            arguments.SetAt(1, _variant_t((IDispatch*)ReadArguments2Ptr));
            arguments.SetAt(2, _variant_t((IDispatch*)ReadArguments3Ptr));
            CComVariant vArguments(arguments);

            // Obtain values. By default, the Value attributes of the nodes will be read.
            CComSafeArray<VARIANT> results;
            results.Attach(ClientPtr->ReadMultipleValues(&vArguments));
            
            // Display results
            for (int i = results.GetLowerBound(); i <= results.GetUpperBound(); i++)
            {
                _ValueResultPtr ValueResultPtr = results[i];

                _variant_t vString;
                vString.ChangeType(VT_BSTR, &ValueResultPtr->Value);
                _tprintf(_T("Value: %s\n"), (LPCTSTR)CW2CT((_bstr_t)vString));
            }

            // Example output:
            //
            //Value: 8
            //Value: -8.06803E+21
            //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^            
        }
         // Release all interface pointers BEFORE calling CoUninitialize()
        CoUninitialize();
    }
}
// This example shows how to read the Value attributes of 3 different nodes at
// once. Using the same method, it is also possible to read multiple attributes
// of the same node.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

class procedure ReadMultipleValues.Main;
var
  Client: EasyUAClient;
  ReadArguments1, ReadArguments2, ReadArguments3: _UAReadArguments;
  Arguments, Results: OleVariant;
  I: Cardinal;
  Result: _ValueResult;
begin
  // Instantiate the client object
  Client := CoEasyUAClient.Create;

  ReadArguments1 := CoUAReadArguments.Create;
  ReadArguments1.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments1.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10845';

  ReadArguments2 := CoUAReadArguments.Create;
  ReadArguments2.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments2.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10853';

  ReadArguments3 := CoUAReadArguments.Create;
  ReadArguments3.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments3.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10855';

  Arguments := VarArrayCreate([0, 2], varVariant);
  Arguments[0] := ReadArguments1;
  Arguments[1] := ReadArguments2;
  Arguments[2] := ReadArguments3;

  // Obtain values. By default, the Value attributes of the nodes will be read.
  TVarData(Results).VType := varArray or varVariant;
  TVarData(Results).VArray := PVarArray(Client.ReadMultipleValues(
    PSafeArray(TVarData(Arguments).VArray)));

  // Display results
  for I := VarArrayLowBound(Results, 1) to VarArrayHighBound(Results, 1) do
  begin
      Result := IInterface(Results[I]) as _ValueResult;
      WriteLn('Value: ', Result.Value);
  end;

  // Example output:
  //
  //Value: 8
  //Value: -8.06803E+21
  //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
end;
// This example shows how to read the Value attributes of 3 different nodes at
// once. Using the same method, it is also possible to read multiple attributes
// of the same node.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// OPC client and subscriber examples in Object Pascal (Delphi) on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-OP .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

class procedure ReadMultipleValues.Main;
var
  Client: OpcLabs_EasyOpcUA_TLB._EasyUAClient;
  ReadArguments1, ReadArguments2, ReadArguments3: _UAReadArguments;
  Arguments, Results: OleVariant;
  I: Cardinal;
  Result: _ValueResult;
begin
  // Instantiate the client object
  Client := CoEasyUAClient.Create;

  ReadArguments1 := CoUAReadArguments.Create;
  ReadArguments1.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments1.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10845';

  ReadArguments2 := CoUAReadArguments.Create;
  ReadArguments2.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments2.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10853';

  ReadArguments3 := CoUAReadArguments.Create;
  ReadArguments3.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments3.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10855';

  Arguments := VarArrayCreate([0, 2], varVariant);
  Arguments[0] := ReadArguments1;
  Arguments[1] := ReadArguments2;
  Arguments[2] := ReadArguments3;

  // Obtain values. By default, the Value attributes of the nodes will be read.
  TVarData(Results).VType := varArray or varVariant;
  TVarData(Results).VArray := PVarArray(Client.ReadMultipleValues(Arguments));

  // Display results
  for I := VarArrayLowBound(Results, 1) to VarArrayHighBound(Results, 1) do
  begin
      Result := IInterface(Results[I]) as _ValueResult;
      if Result.Succeeded then
        WriteLn('Value: ', Result.Value)
      else
        WriteLn('results(', I, ') *** Failure: ', Result.ErrorMessageBrief);
  end;

  VarClear(Results);
  VarClear(Arguments);

  // Example output:
  //
  //Value: 8
  //Value: -8.06803E+21
  //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
end;
// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
// to read multiple attributes of the same node.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// OPC client and subscriber examples in PHP on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-PHP .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

// Instantiate the client object
$Client = new COM("OpcLabs.EasyOpc.UA.EasyUAClient");

$ReadArguments1 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments1->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments1->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845";

$ReadArguments2 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments2->EndpointDescriptor->UrlString = "
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments2->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853";

$ReadArguments3 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments3->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments3->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855";

$arguments[0] = $ReadArguments1;
$arguments[1] = $ReadArguments2;
$arguments[2] = $ReadArguments3;

// Obtain values. By default, the Value attributes of the nodes will be read.
$results = $Client->ReadMultipleValues($arguments);

// Display results
for ($i = 0; $i < count($results); $i++)
{
    $ValueResult = $results[$i];
    if ($ValueResult->Succeeded)
        printf("Value: %s\n", $ValueResult->Value);
    else
        printf("*** Failure: %s\n", $ValueResult->ErrorMessageBrief);
}

// Example output:
//
//Value: 8
//Value: -8.06803E+21
//Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^            
REM This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible
REM to read multiple attributes of the same node.
REM
REM Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
REM OPC client and subscriber examples in Visual Basic on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-VB .
REM Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
REM a commercial license in order to use Online Forums, and we reply to every post.

Public Sub ReadMultipleValues_Main_Command_Click()
    OutputText = ""

    ' Instantiate the client object
    Dim Client As New EasyUAClient

    Dim readArguments1 As New UAReadArguments
    readArguments1.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    readArguments1.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10845"

    Dim ReadArguments2 As New UAReadArguments
    ReadArguments2.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    ReadArguments2.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10853"

    Dim ReadArguments3 As New UAReadArguments
    ReadArguments3.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    ReadArguments3.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10855"

    Dim arguments(2) As Variant
    Set arguments(0) = readArguments1
    Set arguments(1) = ReadArguments2
    Set arguments(2) = ReadArguments3

    ' Obtain values. By default, the Value attributes of the nodes will be read.
    Dim results() As Variant
    results = Client.ReadMultipleValues(arguments)

    ' Display results
    Dim i: For i = LBound(results) To UBound(results)
        Dim Result As valueResult: Set Result = results(i)
        If Result.Succeeded Then
            OutputText = OutputText & "Value: " & Result.value & vbCrLf
        Else
            OutputText = OutputText & "*** Failure: " & Result.ErrorMessageBrief & vbCrLf
        End If
    Next

    ' Example output:
    '
    'Value: 8
    'Value: -8.06803E+21
    'Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
End Sub
Rem This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
Rem to read multiple attributes of the same node.
Rem
Rem Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
Rem OPC client and subscriber examples in VBScript on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-VBScript .
Rem Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
Rem a commercial license in order to use Online Forums, and we reply to every post.

Option Explicit

' Instantiate the client object
Dim Client: Set Client = CreateObject("OpcLabs.EasyOpc.UA.EasyUAClient")

Dim ReadArguments1: Set ReadArguments1 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments1.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments1.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845"

Dim ReadArguments2: Set ReadArguments2 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments2.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments2.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853"

Dim ReadArguments3: Set ReadArguments3 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments3.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments3.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855"

Dim arguments(2)
Set arguments(0) = ReadArguments1
Set arguments(1) = ReadArguments2
Set arguments(2) = ReadArguments3

' Obtain values. By default, the Value attributes of the nodes will be read.
Dim results: results = Client.ReadMultipleValues(arguments)

' Display results
Dim i: For i = LBound(results) To UBound(results)
    Dim ValueResult: Set ValueResult = results(i)
    If ValueResult.Succeeded Then
        WScript.Echo "Value: " & ValueResult.Value
    Else
        WScript.Echo "*** Failure: " & ValueResult.ErrorMessageBrief
    End If
Next

' Example output:
'
'Value: 8
'Value: -8.06803E+21
'Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^            
// This example shows how to read the DataType attributes of 3 different nodes at
// once. Using the same method, it is also possible to read multiple attributes
// of the same node.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// OPC client and subscriber examples in Object Pascal (Delphi) on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-OP .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

class procedure ReadMultipleValues.DataType;
var
  Client: OpcLabs_EasyOpcUA_TLB._EasyUAClient;
  ReadArguments1, ReadArguments2, ReadArguments3: _UAReadArguments;
  Arguments, Results: OleVariant;
  I: Cardinal;
  Result: _ValueResult;
begin
  // Instantiate the client object
  Client := CoEasyUAClient.Create;

  ReadArguments1 := CoUAReadArguments.Create;
  ReadArguments1.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments1.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10845';
  ReadArguments1.AttributeId := UAAttributeId_DataType;

  ReadArguments2 := CoUAReadArguments.Create;
  ReadArguments2.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments2.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10853';
  ReadArguments2.AttributeId := UAAttributeId_DataType;

  ReadArguments3 := CoUAReadArguments.Create;
  ReadArguments3.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments3.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10855';
  ReadArguments3.AttributeId := UAAttributeId_DataType;

  Arguments := VarArrayCreate([0, 2], varVariant);
  Arguments[0] := ReadArguments1;
  Arguments[1] := ReadArguments2;
  Arguments[2] := ReadArguments3;

  // Obtain values. By default, the Value attributes of the nodes will be read.
  TVarData(Results).VType := varArray or varVariant;
  TVarData(Results).VArray := PVarArray(Client.ReadMultipleValues(Arguments));

  // Display results
  for I := VarArrayLowBound(Results, 1) to VarArrayHighBound(Results, 1) do
  begin
      Result := IInterface(Results[I]) as _ValueResult;
      WriteLn;
      if Result.Succeeded then
      begin
          WriteLn('Value: ', Result.Value);
          WriteLn('Value.ExpandedText: ', Result.Value.ExpandedText);
          WriteLn('Value.NamespaceUriString: ', Result.Value.NamespaceUriString);
          WriteLn('Value.NamespaceIndex: ', Result.Value.NamespaceIndex);
          WriteLn('Value.NumericIdentifier: ', Result.Value.NumericIdentifier);
      end
      else
        WriteLn('results(', I, ') *** Failure: ', Result.ErrorMessageBrief);
  end;
  
  VarClear(Results);
  VarClear(Arguments);

  // Example output:
  //
  //
  //Value: SByte
  //Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=2
  //Value.NamespaceUriString: http://opcfoundation.org/UA/
  //Value.NamespaceIndex: 0
  //Value.NumericIdentifier: 2
  //
  //Value: Float
  //Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=10
  //Value.NamespaceUriString: http://opcfoundation.org/UA/
  //Value.NamespaceIndex: 0
  //Value.NumericIdentifier: 10
  //
  //Value: String
  //Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=12
  //Value.NamespaceUriString: http://opcfoundation.org/UA/
  //Value.NamespaceIndex: 0
  //Value.NumericIdentifier: 12
end;
// This example shows how to read the DataType attributes of 3 different nodes at
// once. Using the same method, it is also possible to read multiple attributes
// of the same node.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
// OPC client and subscriber examples in PHP on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-PHP .
// Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
// a commercial license in order to use Online Forums, and we reply to every post.

const UAAttributeId_DataType = 14;

// Instantiate the client object
$Client = new COM("OpcLabs.EasyOpc.UA.EasyUAClient");

$ReadArguments1 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments1->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments1->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845";
$ReadArguments1->AttributeId = UAAttributeId_DataType;

$ReadArguments2 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments2->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments2->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853";
$ReadArguments2->AttributeId = UAAttributeId_DataType;

$ReadArguments3 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments3->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments3->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855";
$ReadArguments3->AttributeId = UAAttributeId_DataType;

$arguments[0] = $ReadArguments1;
$arguments[1] = $ReadArguments2;
$arguments[2] = $ReadArguments3;

// Obtain values. By default, the Value attributes of the nodes will be read.
$results = $Client->ReadMultipleValues($arguments);

// Display results
for ($i = 0; $i < count($results); $i++)
{
    $ValueResult = $results[$i];
    printf("\n");
    if ($ValueResult->Succeeded)
    {
        printf("Value: %s\n", $ValueResult->Value);
        printf("Value.ExpandedText: %s\n", $ValueResult->Value->ExpandedText);
        printf("Value.NamespaceUriString: %s\n", $ValueResult->Value->NamespaceUriString);
        printf("Value.NamespaceIndex: %s\n", $ValueResult->Value->NamespaceIndex);
        printf("Value.NumericIdentifier: %s\n", $ValueResult->Value->NumericIdentifier);
    }
    else
        printf("*** Failure: %s\n", $ValueResult->ErrorMessageBrief);
}

// Example output:
//
//
//Value: SByte
//Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=2
//Value.NamespaceUriString: http://opcfoundation.org/UA/
//Value.NamespaceIndex: 0
//Value.NumericIdentifier: 2
//
//Value: Float
//Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=10
//Value.NamespaceUriString: http://opcfoundation.org/UA/
//Value.NamespaceIndex: 0
//Value.NumericIdentifier: 10
//
//Value: String
//Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=12
//Value.NamespaceUriString: http://opcfoundation.org/UA/
//Value.NamespaceIndex: 0
//Value.NumericIdentifier: 12
Rem This example shows how to read the DataType attributes of 3 different nodes at once. Using the same method, it is also possible 
Rem to read multiple attributes of the same node.
Rem
Rem Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
Rem OPC client and subscriber examples in VBScript on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-VBScript .
Rem Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
Rem a commercial license in order to use Online Forums, and we reply to every post.

Option Explicit

Const UAAttributeId_DataType = 14

' Instantiate the client object
Dim Client: Set Client = CreateObject("OpcLabs.EasyOpc.UA.EasyUAClient")

Dim ReadArguments1: Set ReadArguments1 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments1.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments1.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845"
ReadArguments1.AttributeId = UAAttributeId_DataType

Dim ReadArguments2: Set ReadArguments2 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments2.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments2.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853"
ReadArguments2.AttributeId = UAAttributeId_DataType

Dim ReadArguments3: Set ReadArguments3 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments3.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments3.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855"
ReadArguments3.AttributeId = UAAttributeId_DataType

Dim arguments(2)
Set arguments(0) = ReadArguments1
Set arguments(1) = ReadArguments2
Set arguments(2) = ReadArguments3

' Obtain values.
Dim results: results = Client.ReadMultipleValues(arguments)

' Display results
Dim i: For i = LBound(results) To UBound(results)
    WScript.Echo

    Dim ValueResult: Set ValueResult = results(i)
    If ValueResult.Succeeded Then
        WScript.Echo "Value: " & ValueResult.Value
        On Error Resume Next
        WScript.Echo "Value.ExpandedText: " & ValueResult.Value.ExpandedText
        WScript.Echo "Value.NamespaceUriString: " & ValueResult.Value.NamespaceUriString
        WScript.Echo "Value.NamespaceIndex: " & ValueResult.Value.NamespaceIndex
        WScript.Echo "Value.NumericIdentifier: " & ValueResult.Value.NumericIdentifier
        On Error Goto 0
    Else
        WScript.Echo "*** Failure: " & ValueResult.ErrorMessageBrief
    End If
Next

' Example output:
'
'Value: SByte
'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=2
'Value.NamespaceUriString: http://opcfoundation.org/UA/
'Value.NamespaceIndex: 0
'Value.NumericIdentifier: 2
'
'Value: Float
'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=10
'Value.NamespaceUriString: http://opcfoundation.org/UA/
'Value.NamespaceIndex: 0
'Value.NumericIdentifier: 10
'
'Value: String
'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=12
'Value.NamespaceUriString: http://opcfoundation.org/UA/
'Value.NamespaceIndex: 0
'Value.NumericIdentifier: 12
REM This example shows how to read the DataType attributes of 3 different nodes at once. Using the same method, it is also possible
REM to read multiple attributes of the same node.
REM
REM Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
REM OPC client and subscriber examples in Visual Basic on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-VB .
REM Missing some example? Ask us for it on our Online Forums, https://www.opclabs.com/forum/index ! You do not have to own
REM a commercial license in order to use Online Forums, and we reply to every post.

Public Sub ReadMultipleValues_DataType_Command_Click()
    OutputText = ""
    
    ' Instantiate the client object
    Dim Client As New EasyUAClient

    Dim readArguments1 As New UAReadArguments
    readArguments1.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    readArguments1.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10845"
    readArguments1.AttributeId = UAAttributeId_DataType

    Dim ReadArguments2 As New UAReadArguments
    ReadArguments2.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    ReadArguments2.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10853"
    ReadArguments2.AttributeId = UAAttributeId_DataType

    Dim ReadArguments3 As New UAReadArguments
    ReadArguments3.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    ReadArguments3.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10855"
    ReadArguments3.AttributeId = UAAttributeId_DataType

    Dim arguments(2) As Variant
    Set arguments(0) = readArguments1
    Set arguments(1) = ReadArguments2
    Set arguments(2) = ReadArguments3

    ' Obtain values.
    Dim results() As Variant
    results = Client.ReadMultipleValues(arguments)

    ' Display results
    Dim i: For i = LBound(results) To UBound(results)
        OutputText = OutputText & vbCrLf
        
        Dim Result As valueResult: Set Result = results(i)
        If Result.Succeeded Then
            OutputText = OutputText & "Value: " & Result.value & vbCrLf
            On Error Resume Next
            OutputText = OutputText & "Value.ExpandedText: " & Result.value.expandedText & vbCrLf
            OutputText = OutputText & "Value.NamespaceUriString: " & Result.value.NamespaceUriString & vbCrLf
            OutputText = OutputText & "Value.NamespaceIndex: " & Result.value.NamespaceIndex & vbCrLf
            OutputText = OutputText & "Value.NumericIdentifier: " & Result.value.NumericIdentifier & vbCrLf
            On Error GoTo 0
        Else
            OutputText = OutputText & "*** Failure: " & Result.ErrorMessageBrief & vbCrLf
        End If
    Next

    ' Example output:
    '
    'Value: SByte
    'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=2
    'Value.NamespaceUriString: http://opcfoundation.org/UA/
    'Value.NamespaceIndex: 0
    'Value.NumericIdentifier: 2
    '
    'Value: Float
    'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=10
    'Value.NamespaceUriString: http://opcfoundation.org/UA/
    'Value.NamespaceIndex: 0
    'Value.NumericIdentifier: 10
    '
    'Value: String
    'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=12
    'Value.NamespaceUriString: http://opcfoundation.org/UA/
    'Value.NamespaceIndex: 0
    'Value.NumericIdentifier: 12
End Sub
Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also