Tests whether an OPC UA PubSub connection can be successfully established. Synchronous.
The method returns normally when the test passes. The method throws a OpcLabs.EasyOpc.UA.OperationModel.UAException when there is an error establishing the connection.
Due to asynchronous nature of some communication channels, successful test outcome does not always imply that a connection has been fully established.
The waitMilliseconds parameter is not a timeout in its traditional sense, i.e. a maximum time allowed for the operation. Here, this method actually waits for the time given by waitMilliseconds parameter unless a failure occurs.
Overload List
Requirements
Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows
See Also