OPC Studio User's Guide and Reference
SetPublishingOffsets Method (_UAUadpWriterGroupMessageParameters)



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA.PubSub.Configuration.ComTypes Namespace > _UAUadpWriterGroupMessageParameters Interface : SetPublishingOffsets Method

The value of this parameter cannot be null (Nothing in Visual Basic).

An array that defines the time in milliseconds for the offset in the publishing interval cycle of sending the network message to the network.
Syntax
'Declaration
 
Sub SetPublishingOffsets( _
   ByRef value() As Double _
) 
'Usage
 
Dim instance As _UAUadpWriterGroupMessageParameters
Dim value() As Double
 
instance.SetPublishingOffsets(value)
void SetPublishingOffsets( 
   ref double[] value
)
void SetPublishingOffsets( 
   array<double>^% value
) 

Parameters

value

The value of this parameter cannot be null (Nothing in Visual Basic).

Remarks

The System.Double allows configuration of intervals smaller than a millisecond.

The corresponding field name in OPC-UA PubSub specification is PublishingOffset.

This member is not compatible with VBScript.

This member or type is for use from COM. It is not meant to be used from .NET or Python. Refer to the corresponding .NET member or type instead, if you are developing in .NET or Python.

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows