'Declaration
<ExtensionAttribute()> <NotNullAttribute()> Public Overloads Shared Function GetAccessRightsPropertyValue( _ ByVal client As IEasyDAClient, _ ByVal serverDescriptor As ServerDescriptor, _ ByVal nodeDescriptor As DANodeDescriptor _ ) As DAAccessRight
'Usage
Dim client As IEasyDAClient Dim serverDescriptor As ServerDescriptor Dim nodeDescriptor As DANodeDescriptor Dim value As DAAccessRight value = IEasyDAClientExtension2.GetAccessRightsPropertyValue(client, serverDescriptor, nodeDescriptor)
[Extension()] [NotNull()] public static DAAccessRight GetAccessRightsPropertyValue( IEasyDAClient client, ServerDescriptor serverDescriptor, DANodeDescriptor nodeDescriptor )
[Extension()] [NotNull()] public: static DAAccessRight^ GetAccessRightsPropertyValue( IEasyDAClient^ client, ServerDescriptor^ serverDescriptor, DANodeDescriptor^ nodeDescriptor )
Parameters
- client
- The client object that will perform the operation.
This is typically the OpcLabs.EasyOpc.DataAccess.EasyDAClient object.
The value of this parameter cannot be
null
(Nothing
in Visual Basic). - serverDescriptor
- The OPC server involved in the operation.
Because the OpcLabs.EasyOpc.ServerDescriptor has an implicit conversion from System.Guid, System.String and OpcLabs.EasyOpc.ServerElement, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a GUID (representing the CLSID of the server), a string (representing the so-called OPC server descriptor string, such as a ProgID or the URL of the server), or a OpcLabs.EasyOpc.ServerElement object (result from OPC browsing), in place of this parameter, and the corresponding OPC server descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the OpcLabs.EasyOpc.ServerDescriptor.FromGuid, OpcLabs.EasyOpc.ServerDescriptor.FromString or OpcLabs.EasyOpc.ServerDescriptor.FromServerElement static method instead.
The value of this parameter cannot be
null
(Nothing
in Visual Basic). - nodeDescriptor
- The descriptor of the OPC node involved in the operation.
Because the OpcLabs.EasyOpc.DataAccess.DANodeDescriptor has an implicit conversion from System.String and OpcLabs.EasyOpc.DataAccess.AddressSpace.DANodeElement, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use a string (representing the qualified name of the node), or a OpcLabs.EasyOpc.DataAccess.AddressSpace.DANodeElement object (result from OPC browsing), in place of this parameter, and the corresponding OPC DA node descriptor will be constructed automatically. When the implicit conversion operators are not supported (such as with Python.NET), you can use the FromString or FromDANodeElement static method instead.
The value of this parameter cannot be
null
(Nothing
in Visual Basic).
Return Value
Because there is an implicit conversion from OpcLabs.EasyOpc.DataAccess.DAAccessRight to System.Int64 and OpcLabs.EasyOpc.DataAccess.DAAccessRights, in languages that support implicit conversion operators (such as C# or VB.NET), you can simply use the return value in place of a System.Int64 (representing the numerical value of the access rights), or in place a OpcLabs.EasyOpc.DataAccess.DAAccessRights enumeration value. When the implicit conversion operators are not supported (such as with Python.NET), you can use the ToInt64 or ToDAAccessRights static method instead.
This method never returns null