OPC Studio User's Guide and Reference
RetrialDelay Property (UAClientSessionParameters)



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA.Engine Namespace > UAClientSessionParameters Class : RetrialDelay Property
A delay before the component will try to reconnect the session, if it failed to connect it previously, or a serious failure occurred related to the session (in milliseconds).
Syntax
'Declaration
 
<DefaultValueAttribute(10000)>
<UnitAttribute("ms")>
Public Property RetrialDelay As Integer
'Usage
 
Dim instance As UAClientSessionParameters
Dim value As Integer
 
instance.RetrialDelay = value
 
value = instance.RetrialDelay
[DefaultValue(10000)]
[Unit("ms")]
public int RetrialDelay {get; set;}
[DefaultValue(10000)]
[Unit("ms")]
public:
property int RetrialDelay {
   int get();
   void set (    int value);
}
Remarks

The reconnection will be done by the component automatically, as long as there are any open subscriptions, or an explicit UA operation is requested. The static EasyUAClient.RetryAll method can be used to force a retrial on all objects that are in a failure state.

In order to obtain or modify this parameter, in the default state (when OpcLabs.EasyOpc.UA.EasyUAClientCore.Isolated equals to false), access UAClientAdaptableParameters.SessionParameters property of static OpcLabs.EasyOpc.UA.EasyUAClientCore.AdaptableParameters. If you have set OpcLabs.EasyOpc.UA.EasyUAClientCore.Isolated to true, you need to access UAClientAdaptableParameters.SessionParameters property of OpcLabs.EasyOpc.UA.EasyUAClientCore.IsolatedParameters.

Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also