OPC Studio User's Guide and Reference
ReadMultipleValues Method (_EasyUAClient)
Example 



OpcLabs.EasyOpcUA Assembly > OpcLabs.EasyOpc.UA.ComTypes Namespace > _EasyUAClient Interface : ReadMultipleValues Method
Array of OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments. Array of argument objects specifying what to read from an OPC-UA server.
Reads values of multiple attributes. Reads values of multiple attributes, using array of argument objects as an input.
Reads values of multiple attributes.
Syntax
'Declaration
 
<ElementsNotNullAttribute()>
<NotNullAttribute()>
Function ReadMultipleValues( _
   ByVal readArgumentsArray As Object _
) As Object()
'Usage
 
Dim instance As _EasyUAClient
Dim readArgumentsArray As Object
Dim value() As Object
 
value = instance.ReadMultipleValues(readArgumentsArray)
[ElementsNotNull()]
[NotNull()]
object[] ReadMultipleValues( 
   object readArgumentsArray
)
[ElementsNotNull()]
[NotNull()]
array<Object^>^ ReadMultipleValues( 
   Object^ readArgumentsArray
) 

Parameters

readArgumentsArray
Array of OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments. Array of argument objects specifying what to read from an OPC-UA server.

Return Value

Array of OpcLabs.BaseLib.OperationModel.ValueResult. Returns an array of value objects. Each object contains the actual value of an attribute. The indices of elements in the output array are the same as those in the input array, readArgumentsArray.
Exceptions
ExceptionDescription

A null reference (Nothing in Visual Basic) is passed to a method that does not accept it as a valid argument.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

Remarks

The status codes of attributes should be 'good'; otherwise, a OpcLabs.BaseLib.OperationModel.ValueResult.Value of that attribute is not valid, and OpcLabs.BaseLib.OperationModel.OperationResult.Exception contains a non-null exception.

The size of the input array will become the size of the output array. The element positions (indices) in the output array are the same as in the input array.

 

This is a multiple-operation method. In a properly written program, it does not throw any exceptions. You should therefore not put try/catch statements or similar constructs around calls to this method. The only exceptions thrown by this method are for usage errors, i.e. when your code violates the usage contract of the method, such as passing in invalid arguments or calling the method when the state of the object does not allow it. Any operation-related errors (i.e. errors that depend on external conditions that your code cannot reliably check) are indicated in the result objects returned by the method. For more information, see Multiple-operation Methods and Do not catch any exceptions with asynchronous or multiple-operation methods.
Example

.NET

.NET

COM

COM

// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
// to read multiple attributes of the same node.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

using System;
using OpcLabs.BaseLib.OperationModel;
using OpcLabs.EasyOpc.UA;
using OpcLabs.EasyOpc.UA.OperationModel;

namespace UADocExamples._EasyUAClient
{
    partial class ReadMultipleValues
    {
        public static void Main1()
        {
            UAEndpointDescriptor endpointDescriptor =
                "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
            // or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported)
            // or "https://opcua.demo-this.com:51212/UA/SampleServer/"

            // Instantiate the client object.
            var client = new EasyUAClient();

            // Obtain values. By default, the Value attributes of the nodes will be read.
            ValueResult[] valueResultArray = client.ReadMultipleValues(new[]
                {
                    new UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10845"),
                    new UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10853"),
                    new UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10855")
                });

            // Display results.
            foreach (ValueResult valueResult in valueResultArray)
            {
                if (valueResult.Succeeded)
                    Console.WriteLine($"Value: {valueResult.Value}");
                else
                    Console.WriteLine($"*** Failure: {valueResult.ErrorMessageBrief}");
            }


            // Example output:
            //
            //Value: 8
            //Value: -8.06803E+21
            //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^            
        }
    }
}
# This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
# to read multiple attributes of the same node.
#
# Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

#requires -Version 5.1
using namespace OpcLabs.EasyOpc.UA
using namespace OpcLabs.EasyOpc.UA.OperationModel

# The path below assumes that the current directory is [ProductDir]/Examples-NET/PowerShell/Windows .
Add-Type -Path "../../../Components/Opclabs.QuickOpc/net472/OpcLabs.EasyOpcUA.dll"
Add-Type -Path "../../../Components/Opclabs.QuickOpc/net472/OpcLabs.EasyOpcUAComponents.dll"

[UAEndpointDescriptor]$endpointDescriptor =
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
# or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported)
# or "https://opcua.demo-this.com:51212/UA/SampleServer/"

# Instantiate the client object.
$client = New-Object EasyUAClient

# Obtain values. By default, the Value attributes of the nodes will be read.
$valueResultArray = $client.ReadMultipleValues([UAReadArguments[]]@(
        (New-Object UAReadArguments($endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10845")), 
        (New-Object UAReadArguments($endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10853")), 
        (New-Object UAReadArguments($endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10855"))
    ))

foreach ($valueResult in $valueResultArray) {
    if ($valueResult.Succeeded) {
        Write-Host "Value: $($valueResult.Value)"
    }
    else {
        Write-Host "*** Failure: $($valueResult.ErrorMessageBrief)"
    }
}


# Example output:
#
#Value: 8
#Value: -8.06803E+21
#Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^            
# This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible
# to read multiple attributes of the same node.
#
# Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
# OPC client and subscriber examples in Python on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-Python .
# The QuickOPC package is needed. Install it using "pip install opclabs_quickopc".
import opclabs_quickopc
import time

# Import .NET namespaces.
from OpcLabs.EasyOpc.UA import *
from OpcLabs.EasyOpc.UA.OperationModel import *


endpointDescriptor = UAEndpointDescriptor('opc.tcp://opcua.demo-this.com:51210/UA/SampleServer')
# or 'http://opcua.demo-this.com:51211/UA/SampleServer' (currently not supported)
# or 'https://opcua.demo-this.com:51212/UA/SampleServer/'

# Instantiate the client object.
client = EasyUAClient()

# Obtain values. By default, the Value attributes of the nodes will be read.
valueResultArray = IEasyUAClientExtension.ReadMultipleValues(client, [
    UAReadArguments(endpointDescriptor, UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10845')),
    UAReadArguments(endpointDescriptor, UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10853')),
    UAReadArguments(endpointDescriptor, UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10855')),
    ])

# Display results.
for valueResult in valueResultArray:
    if valueResult.Succeeded:
        print('Value: ', valueResult.Value, sep='')
    else:
        print('*** Failure: ', valueResult.ErrorMessageBrief, sep='')

print()
print('Finished.')
' This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
' to read multiple attributes of the same node.
'
' Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

Imports System
Imports OpcLabs.BaseLib.OperationModel
Imports OpcLabs.EasyOpc.UA
Imports OpcLabs.EasyOpc.UA.OperationModel

Namespace _EasyUAClient
    Partial Friend Class ReadMultipleValues
        Public Shared Sub Main1()

            ' Define which server we will work with.
            Dim endpointDescriptor As UAEndpointDescriptor =
                    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
            ' or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported)
            ' or "https://opcua.demo-this.com:51212/UA/SampleServer/"

            ' Instantiate the client object
            Dim client = New EasyUAClient()

            ' Obtain values. By default, the Value attributes of the nodes will be read.
            Dim valueResultArray() As ValueResult = client.ReadMultipleValues(New UAReadArguments() _
               {
                   New UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10845"),
                   New UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10853"),
                   New UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10855")
               }
            )

            ' Display results
            For Each valueResult As ValueResult In valueResultArray
                If valueResult.Succeeded Then
                    Console.WriteLine("Value: {0}", valueResult.Value)
                Else
                    Console.WriteLine("*** Failure: {0}", valueResult.ErrorMessageBrief)
                End If
            Next valueResult

            ' Example output:
            '
            'Value: 8
            'Value: -8.06803E+21
            'Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^            
        End Sub
    End Class
End Namespace
// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
// to read multiple attributes of the same node.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

using System;
using OpcLabs.BaseLib.OperationModel;
using OpcLabs.EasyOpc.UA;
using OpcLabs.EasyOpc.UA.AddressSpace;
using OpcLabs.EasyOpc.UA.OperationModel;

namespace UADocExamples._EasyUAClient
{
    partial class ReadMultipleValues
    {
        public static void DataType()
        {
            UAEndpointDescriptor endpointDescriptor =
                "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
            // or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported)
            // or "https://opcua.demo-this.com:51212/UA/SampleServer/"

            // Instantiate the client object.
            var client = new EasyUAClient();

            // Obtain values.
            ValueResult[] valueResultArray = client.ReadMultipleValues(new[]
                {
                    new UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10845", UAAttributeId.DataType),
                    new UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10853", UAAttributeId.DataType),
                    new UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10855", UAAttributeId.DataType)
                });

            // Display results.
            foreach (ValueResult valueResult in valueResultArray)
            {
                Console.WriteLine();

                if (valueResult.Succeeded)
                {
                    Console.WriteLine($"Value: {valueResult.Value}");
                    var dataTypeId = valueResult.Value as UANodeId;
                    if (!(dataTypeId is null))
                    {
                        Console.WriteLine($"Value.ExpandedText: {dataTypeId.ExpandedText}");
                        Console.WriteLine($"Value.NamespaceUriString: {dataTypeId.NamespaceUriString}");
                        Console.WriteLine($"Value.NamespaceIndex: {dataTypeId.NamespaceIndex}");
                        Console.WriteLine($"Value.NumericIdentifier: {dataTypeId.NumericIdentifier}");
                    }
                }
                else
                    Console.WriteLine($"*** Failure: {valueResult.ErrorMessageBrief}");
            }

            // Example output:
            //
            //Value: SByte
            //Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=2
            //Value.NamespaceUriString: http://opcfoundation.org/UA/
            //Value.NamespaceIndex: 0
            //Value.NumericIdentifier: 2
            //
            //Value: Float
            //Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=10
            //Value.NamespaceUriString: http://opcfoundation.org/UA/
            //Value.NamespaceIndex: 0
            //Value.NumericIdentifier: 10
            //
            //Value: String
            //Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=12
            //Value.NamespaceUriString: http://opcfoundation.org/UA/
            //Value.NamespaceIndex: 0
            //Value.NumericIdentifier: 12
        }
    }
}
# This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
# to read multiple attributes of the same node.
#
# Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

#requires -Version 5.1
using namespace OpcLabs.EasyOpc.UA
using namespace OpcLabs.EasyOpc.UA.AddressSpace
using namespace OpcLabs.EasyOpc.UA.OperationModel

# The path below assumes that the current directory is [ProductDir]/Examples-NET/PowerShell/Windows .
Add-Type -Path "../../../Components/Opclabs.QuickOpc/net472/OpcLabs.EasyOpcUA.dll"
Add-Type -Path "../../../Components/Opclabs.QuickOpc/net472/OpcLabs.EasyOpcUAComponents.dll"

[UAEndpointDescriptor]$endpointDescriptor =
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
# or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported)
# or "https://opcua.demo-this.com:51212/UA/SampleServer/"

# Instantiate the client object.
$client = New-Object EasyUAClient

# Obtain values. 
$valueResultArray = $client.ReadMultipleValues([UAReadArguments[]]@(
        (New-Object UAReadArguments($endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10845", [UAAttributeId]::DataType)), 
        (New-Object UAReadArguments($endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10853", [UAAttributeId]::DataType)), 
        (New-Object UAReadArguments($endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10855", [UAAttributeId]::DataType))
    ))

foreach ($valueResult in $valueResultArray) {
    Write-Host

    if ($valueResult.Succeeded) {
        Write-Host "Value: $($valueResult.Value)"
        [UANodeId]$dataTypeId = $valueResult.Value;
        if ($dataTypeId -ne $null) {
            Write-Host "Value.ExpandedText: $($dataTypeId.ExpandedText)"
            Write-Host "Value.NamespaceUriString: $($dataTypeId.NamespaceUriString)"
            Write-Host "Value.NamespaceIndex: $($dataTypeId.NamespaceIndex)"
            Write-Host "Value.NumericIdentifier: $($dataTypeId.NumericIdentifier)"
        }
    }
    else {
        Write-Host "*** Failure: $($valueResult.ErrorMessageBrief)"
    }
}


# Example output:
#
#Value: SByte
#Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=2
#Value.NamespaceUriString: http://opcfoundation.org/UA/
#Value.NamespaceIndex: 0
#Value.NumericIdentifier: 2
#
#Value: Float
#Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=10
#Value.NamespaceUriString: http://opcfoundation.org/UA/
#Value.NamespaceIndex: 0
#Value.NumericIdentifier: 10
#
#Value: String
#Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=12
#Value.NamespaceUriString: http://opcfoundation.org/UA/
#Value.NamespaceIndex: 0
#Value.NumericIdentifier: 12
# This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also
# possible to read multiple attributes of the same node.
#
# Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .
# OPC client and subscriber examples in Python on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-Python .
# The QuickOPC package is needed. Install it using "pip install opclabs_quickopc".
import opclabs_quickopc
import time

# Import .NET namespaces.
from OpcLabs.EasyOpc.UA import *
from OpcLabs.EasyOpc.UA.AddressSpace import *
from OpcLabs.EasyOpc.UA.OperationModel import *


endpointDescriptor = UAEndpointDescriptor('opc.tcp://opcua.demo-this.com:51210/UA/SampleServer')
# or 'http://opcua.demo-this.com:51211/UA/SampleServer' (currently not supported)
# or 'https://opcua.demo-this.com:51212/UA/SampleServer/'

# Instantiate the client object.
client = EasyUAClient()

# Obtain values. By default, the Value attributes of the nodes will be read.
valueResultArray = IEasyUAClientExtension.ReadMultipleValues(client, [
    UAReadArguments(endpointDescriptor, UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10845'),
                    UAAttributeId.DataType),
    UAReadArguments(endpointDescriptor, UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10853'),
                    UAAttributeId.DataType),
    UAReadArguments(endpointDescriptor, UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10855'),
                    UAAttributeId.DataType),
    ])

# Display results.
for valueResult in valueResultArray:
    print()
    #
    if valueResult.Succeeded:
        print('Value: ', valueResult.Value, sep='')
        if isinstance(valueResult.Value, UANodeId):
            dataTypeId = valueResult.Value
            print('dataTypeId.ExpandedText: ', dataTypeId.ExpandedText, sep='')
            print('dataTypeId.NamespaceUriString: ', dataTypeId.NamespaceUriString, sep='')
            print('dataTypeId.NamespaceIndex: ', dataTypeId.NamespaceIndex, sep='')
            print('dataTypeId.NumericIdentifier: ', dataTypeId.NumericIdentifier, sep='')
    else:
        print('*** Failure: ', valueResult.ErrorMessageBrief, sep='')

print()
print('Finished.')
' This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
' to read multiple attributes of the same node.
'
' Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

Imports System
Imports OpcLabs.BaseLib.OperationModel
Imports OpcLabs.EasyOpc.UA
Imports OpcLabs.EasyOpc.UA.AddressSpace
Imports OpcLabs.EasyOpc.UA.OperationModel

Namespace _EasyUAClient
    Partial Friend Class ReadMultipleValues
        Public Shared Sub DataType()

            ' Define which server we will work with.
            Dim endpointDescriptor As UAEndpointDescriptor =
                    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
            ' or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported)
            ' or "https://opcua.demo-this.com:51212/UA/SampleServer/"

            ' Instantiate the client object
            Dim client = New EasyUAClient()

            ' Obtain values.
            Dim valueResultArray() As ValueResult = client.ReadMultipleValues(New UAReadArguments() _
               {
                   New UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10845", UAAttributeId.DataType),
                   New UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10853", UAAttributeId.DataType),
                   New UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10855", UAAttributeId.DataType)
               }
            )

            ' Display results
            For Each valueResult As ValueResult In valueResultArray
                Console.WriteLine()

                If valueResult.Succeeded Then
                    Console.WriteLine("Value: {0}", valueResult.Value)
                    Dim dataTypeId = CType(valueResult.Value, UANodeId)
                    If Not dataTypeId Is Nothing Then
                        Console.WriteLine("Value.ExpandedText: {0}", dataTypeId.ExpandedText)
                        Console.WriteLine("Value.NamespaceUriString: {0}", dataTypeId.NamespaceUriString)
                        Console.WriteLine("Value.NamespaceIndex: {0}", dataTypeId.NamespaceIndex)
                        Console.WriteLine("Value.NumericIdentifier: {0}", dataTypeId.NumericIdentifier)
                    End If
                Else
                    Console.WriteLine("*** Failure: {0}", valueResult.ErrorMessageBrief)
                End If
            Next valueResult

            ' Example output:
            '
            'Value: SByte
            'Value.ExpandedText: nsu = http : //opcfoundation.org/UA/ ;i=2
            'Value.NamespaceUriString: http : //opcfoundation.org/UA/
            'Value.NamespaceIndex: 0
            'Value.NumericIdentifier: 2
            '
            'Value: Float
            'Value.ExpandedText: nsu = http : //opcfoundation.org/UA/ ;i=10
            'Value.NamespaceUriString: http : //opcfoundation.org/UA/
            'Value.NamespaceIndex: 0
            'Value.NumericIdentifier: 10
            '
            'Value: String
            'Value.ExpandedText: nsu = http : //opcfoundation.org/UA/ ;i=12
            'Value.NamespaceUriString: http : //opcfoundation.org/UA/
            'Value.NamespaceIndex: 0
            'Value.NumericIdentifier: 12
        End Sub
    End Class
End Namespace
// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
// to read multiple attributes of the same node.
//
// Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

#include "stdafx.h"    // Includes "QuickOpc.h", and other commonly used files
#include <atlsafe.h>
#include "ReadMultipleValues.h"

namespace _EasyUAClient
{
    void ReadMultipleValues::Main()
    {
        // Initialize the COM library
        CoInitializeEx(NULL, COINIT_MULTITHREADED);
        {
            // Instantiate the client object
            _EasyUAClientPtr ClientPtr(__uuidof(EasyUAClient));

            _UAReadArgumentsPtr ReadArguments1Ptr(_uuidof(UAReadArguments));
            ReadArguments1Ptr->EndpointDescriptor->UrlString = 
                //L"http://opcua.demo-this.com:51211/UA/SampleServer";
                L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
            ReadArguments1Ptr->NodeDescriptor->NodeId->ExpandedText = L"nsu=http://test.org/UA/Data/ ;i=10845";

            _UAReadArgumentsPtr ReadArguments2Ptr(_uuidof(UAReadArguments));
            ReadArguments2Ptr->EndpointDescriptor->UrlString = 
                //L"http://opcua.demo-this.com:51211/UA/SampleServer";
                L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
            ReadArguments2Ptr->NodeDescriptor->NodeId->ExpandedText = L"nsu=http://test.org/UA/Data/ ;i=10853";

            _UAReadArgumentsPtr ReadArguments3Ptr(_uuidof(UAReadArguments));
            ReadArguments3Ptr->EndpointDescriptor->UrlString = 
                //L"http://opcua.demo-this.com:51211/UA/SampleServer";
                L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
            ReadArguments3Ptr->NodeDescriptor->NodeId->ExpandedText = L"nsu=http://test.org/UA/Data/ ;i=10855";

            CComSafeArray<VARIANT> arguments(3);
            arguments.SetAt(0, _variant_t((IDispatch*)ReadArguments1Ptr));
            arguments.SetAt(1, _variant_t((IDispatch*)ReadArguments2Ptr));
            arguments.SetAt(2, _variant_t((IDispatch*)ReadArguments3Ptr));
            CComVariant vArguments(arguments);

            // Obtain values. By default, the Value attributes of the nodes will be read.
            CComSafeArray<VARIANT> results;
            results.Attach(ClientPtr->ReadMultipleValues(&vArguments));
            
            // Display results
            for (int i = results.GetLowerBound(); i <= results.GetUpperBound(); i++)
            {
                _ValueResultPtr ValueResultPtr = results[i];

                _variant_t vString;
                vString.ChangeType(VT_BSTR, &ValueResultPtr->Value);
                _tprintf(_T("Value: %s\n"), (LPCTSTR)CW2CT((_bstr_t)vString));
            }

            // Example output:
            //
            //Value: 8
            //Value: -8.06803E+21
            //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^            
        }
         // Release all interface pointers BEFORE calling CoUninitialize()
        CoUninitialize();
    }
}
// This example shows how to read the Value attributes of 3 different nodes at
// once. Using the same method, it is also possible to read multiple attributes
// of the same node.
//
// Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

class procedure ReadMultipleValues.Main;
var
  Client: EasyUAClient;
  ReadArguments1, ReadArguments2, ReadArguments3: _UAReadArguments;
  Arguments, Results: OleVariant;
  I: Cardinal;
  Result: _ValueResult;
begin
  // Instantiate the client object
  Client := CoEasyUAClient.Create;

  ReadArguments1 := CoUAReadArguments.Create;
  ReadArguments1.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments1.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10845';

  ReadArguments2 := CoUAReadArguments.Create;
  ReadArguments2.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments2.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10853';

  ReadArguments3 := CoUAReadArguments.Create;
  ReadArguments3.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments3.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10855';

  Arguments := VarArrayCreate([0, 2], varVariant);
  Arguments[0] := ReadArguments1;
  Arguments[1] := ReadArguments2;
  Arguments[2] := ReadArguments3;

  // Obtain values. By default, the Value attributes of the nodes will be read.
  TVarData(Results).VType := varArray or varVariant;
  TVarData(Results).VArray := PVarArray(Client.ReadMultipleValues(
    PSafeArray(TVarData(Arguments).VArray)));

  // Display results
  for I := VarArrayLowBound(Results, 1) to VarArrayHighBound(Results, 1) do
  begin
      Result := IInterface(Results[I]) as _ValueResult;
      WriteLn('Value: ', Result.Value);
  end;

  // Example output:
  //
  //Value: 8
  //Value: -8.06803E+21
  //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
end;
// This example shows how to read the Value attributes of 3 different nodes at
// once. Using the same method, it is also possible to read multiple attributes
// of the same node.
//
// Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

class procedure ReadMultipleValues.Main;
var
  Client: OpcLabs_EasyOpcUA_TLB._EasyUAClient;
  ReadArguments1, ReadArguments2, ReadArguments3: _UAReadArguments;
  Arguments, Results: OleVariant;
  I: Cardinal;
  Result: _ValueResult;
begin
  // Instantiate the client object
  Client := CoEasyUAClient.Create;

  ReadArguments1 := CoUAReadArguments.Create;
  ReadArguments1.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments1.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10845';

  ReadArguments2 := CoUAReadArguments.Create;
  ReadArguments2.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments2.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10853';

  ReadArguments3 := CoUAReadArguments.Create;
  ReadArguments3.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments3.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10855';

  Arguments := VarArrayCreate([0, 2], varVariant);
  Arguments[0] := ReadArguments1;
  Arguments[1] := ReadArguments2;
  Arguments[2] := ReadArguments3;

  // Obtain values. By default, the Value attributes of the nodes will be read.
  TVarData(Results).VType := varArray or varVariant;
  TVarData(Results).VArray := PVarArray(Client.ReadMultipleValues(Arguments));

  // Display results
  for I := VarArrayLowBound(Results, 1) to VarArrayHighBound(Results, 1) do
  begin
      Result := IInterface(Results[I]) as _ValueResult;
      if Result.Succeeded then
        WriteLn('Value: ', Result.Value)
      else
        WriteLn('results(', I, ') *** Failure: ', Result.ErrorMessageBrief);
  end;

  VarClear(Results);
  VarClear(Arguments);

  // Example output:
  //
  //Value: 8
  //Value: -8.06803E+21
  //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
end;
// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
// to read multiple attributes of the same node.
//
// Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

// Instantiate the client object
$Client = new COM("OpcLabs.EasyOpc.UA.EasyUAClient");

$ReadArguments1 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments1->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments1->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845";

$ReadArguments2 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments2->EndpointDescriptor->UrlString = "
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments2->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853";

$ReadArguments3 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments3->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments3->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855";

$arguments[0] = $ReadArguments1;
$arguments[1] = $ReadArguments2;
$arguments[2] = $ReadArguments3;

// Obtain values. By default, the Value attributes of the nodes will be read.
$results = $Client->ReadMultipleValues($arguments);

// Display results
for ($i = 0; $i < count($results); $i++)
{
    $ValueResult = $results[$i];
    if ($ValueResult->Succeeded)
        printf("Value: %s\n", $ValueResult->Value);
    else
        printf("*** Failure: %s\n", $ValueResult->ErrorMessageBrief);
}

// Example output:
//
//Value: 8
//Value: -8.06803E+21
//Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^            
REM This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible
REM to read multiple attributes of the same node.
REM
REM Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

Public Sub ReadMultipleValues_Main_Command_Click()
    OutputText = ""

    ' Instantiate the client object
    Dim Client As New EasyUAClient

    Dim readArguments1 As New UAReadArguments
    readArguments1.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    readArguments1.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10845"

    Dim ReadArguments2 As New UAReadArguments
    ReadArguments2.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    ReadArguments2.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10853"

    Dim ReadArguments3 As New UAReadArguments
    ReadArguments3.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    ReadArguments3.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10855"

    Dim arguments(2) As Variant
    Set arguments(0) = readArguments1
    Set arguments(1) = ReadArguments2
    Set arguments(2) = ReadArguments3

    ' Obtain values. By default, the Value attributes of the nodes will be read.
    Dim results() As Variant
    results = Client.ReadMultipleValues(arguments)

    ' Display results
    Dim i: For i = LBound(results) To UBound(results)
        Dim Result As valueResult: Set Result = results(i)
        If Result.Succeeded Then
            OutputText = OutputText & "Value: " & Result.value & vbCrLf
        Else
            OutputText = OutputText & "*** Failure: " & Result.ErrorMessageBrief & vbCrLf
        End If
    Next

    ' Example output:
    '
    'Value: 8
    'Value: -8.06803E+21
    'Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
End Sub
Rem This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible 
Rem to read multiple attributes of the same node.
Rem
Rem Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

Option Explicit

' Instantiate the client object
Dim Client: Set Client = CreateObject("OpcLabs.EasyOpc.UA.EasyUAClient")

Dim ReadArguments1: Set ReadArguments1 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments1.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments1.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845"

Dim ReadArguments2: Set ReadArguments2 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments2.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments2.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853"

Dim ReadArguments3: Set ReadArguments3 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments3.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments3.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855"

Dim arguments(2)
Set arguments(0) = ReadArguments1
Set arguments(1) = ReadArguments2
Set arguments(2) = ReadArguments3

' Obtain values. By default, the Value attributes of the nodes will be read.
Dim results: results = Client.ReadMultipleValues(arguments)

' Display results
Dim i: For i = LBound(results) To UBound(results)
    Dim ValueResult: Set ValueResult = results(i)
    If ValueResult.Succeeded Then
        WScript.Echo "Value: " & ValueResult.Value
    Else
        WScript.Echo "*** Failure: " & ValueResult.ErrorMessageBrief
    End If
Next

' Example output:
'
'Value: 8
'Value: -8.06803E+21
'Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^            
// This example shows how to read the DataType attributes of 3 different nodes at
// once. Using the same method, it is also possible to read multiple attributes
// of the same node.
//
// Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

class procedure ReadMultipleValues.DataType;
var
  Client: OpcLabs_EasyOpcUA_TLB._EasyUAClient;
  ReadArguments1, ReadArguments2, ReadArguments3: _UAReadArguments;
  Arguments, Results: OleVariant;
  I: Cardinal;
  Result: _ValueResult;
begin
  // Instantiate the client object
  Client := CoEasyUAClient.Create;

  ReadArguments1 := CoUAReadArguments.Create;
  ReadArguments1.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments1.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10845';
  ReadArguments1.AttributeId := UAAttributeId_DataType;

  ReadArguments2 := CoUAReadArguments.Create;
  ReadArguments2.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments2.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10853';
  ReadArguments2.AttributeId := UAAttributeId_DataType;

  ReadArguments3 := CoUAReadArguments.Create;
  ReadArguments3.EndpointDescriptor.UrlString := 
    //'http://opcua.demo-this.com:51211/UA/SampleServer';
    //'https://opcua.demo-this.com:51212/UA/SampleServer/';
    'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer';
  ReadArguments3.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10855';
  ReadArguments3.AttributeId := UAAttributeId_DataType;

  Arguments := VarArrayCreate([0, 2], varVariant);
  Arguments[0] := ReadArguments1;
  Arguments[1] := ReadArguments2;
  Arguments[2] := ReadArguments3;

  // Obtain values. By default, the Value attributes of the nodes will be read.
  TVarData(Results).VType := varArray or varVariant;
  TVarData(Results).VArray := PVarArray(Client.ReadMultipleValues(Arguments));

  // Display results
  for I := VarArrayLowBound(Results, 1) to VarArrayHighBound(Results, 1) do
  begin
      Result := IInterface(Results[I]) as _ValueResult;
      WriteLn;
      if Result.Succeeded then
      begin
          WriteLn('Value: ', Result.Value);
          WriteLn('Value.ExpandedText: ', Result.Value.ExpandedText);
          WriteLn('Value.NamespaceUriString: ', Result.Value.NamespaceUriString);
          WriteLn('Value.NamespaceIndex: ', Result.Value.NamespaceIndex);
          WriteLn('Value.NumericIdentifier: ', Result.Value.NumericIdentifier);
      end
      else
        WriteLn('results(', I, ') *** Failure: ', Result.ErrorMessageBrief);
  end;
  
  VarClear(Results);
  VarClear(Arguments);

  // Example output:
  //
  //
  //Value: SByte
  //Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=2
  //Value.NamespaceUriString: http://opcfoundation.org/UA/
  //Value.NamespaceIndex: 0
  //Value.NumericIdentifier: 2
  //
  //Value: Float
  //Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=10
  //Value.NamespaceUriString: http://opcfoundation.org/UA/
  //Value.NamespaceIndex: 0
  //Value.NumericIdentifier: 10
  //
  //Value: String
  //Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=12
  //Value.NamespaceUriString: http://opcfoundation.org/UA/
  //Value.NamespaceIndex: 0
  //Value.NumericIdentifier: 12
end;
// This example shows how to read the DataType attributes of 3 different nodes at
// once. Using the same method, it is also possible to read multiple attributes
// of the same node.
//
// Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

const UAAttributeId_DataType = 14;

// Instantiate the client object
$Client = new COM("OpcLabs.EasyOpc.UA.EasyUAClient");

$ReadArguments1 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments1->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments1->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845";
$ReadArguments1->AttributeId = UAAttributeId_DataType;

$ReadArguments2 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments2->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments2->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853";
$ReadArguments2->AttributeId = UAAttributeId_DataType;

$ReadArguments3 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments");
$ReadArguments3->EndpointDescriptor->UrlString = 
    //"http://opcua.demo-this.com:51211/UA/SampleServer";
    //"https://opcua.demo-this.com:51212/UA/SampleServer/";
    "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer";
$ReadArguments3->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855";
$ReadArguments3->AttributeId = UAAttributeId_DataType;

$arguments[0] = $ReadArguments1;
$arguments[1] = $ReadArguments2;
$arguments[2] = $ReadArguments3;

// Obtain values. By default, the Value attributes of the nodes will be read.
$results = $Client->ReadMultipleValues($arguments);

// Display results
for ($i = 0; $i < count($results); $i++)
{
    $ValueResult = $results[$i];
    printf("\n");
    if ($ValueResult->Succeeded)
    {
        printf("Value: %s\n", $ValueResult->Value);
        printf("Value.ExpandedText: %s\n", $ValueResult->Value->ExpandedText);
        printf("Value.NamespaceUriString: %s\n", $ValueResult->Value->NamespaceUriString);
        printf("Value.NamespaceIndex: %s\n", $ValueResult->Value->NamespaceIndex);
        printf("Value.NumericIdentifier: %s\n", $ValueResult->Value->NumericIdentifier);
    }
    else
        printf("*** Failure: %s\n", $ValueResult->ErrorMessageBrief);
}

// Example output:
//
//
//Value: SByte
//Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=2
//Value.NamespaceUriString: http://opcfoundation.org/UA/
//Value.NamespaceIndex: 0
//Value.NumericIdentifier: 2
//
//Value: Float
//Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=10
//Value.NamespaceUriString: http://opcfoundation.org/UA/
//Value.NamespaceIndex: 0
//Value.NumericIdentifier: 10
//
//Value: String
//Value.ExpandedText: nsu=http://opcfoundation.org/UA/;i=12
//Value.NamespaceUriString: http://opcfoundation.org/UA/
//Value.NamespaceIndex: 0
//Value.NumericIdentifier: 12
Rem This example shows how to read the DataType attributes of 3 different nodes at once. Using the same method, it is also possible 
Rem to read multiple attributes of the same node.
Rem
Rem Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

Option Explicit

Const UAAttributeId_DataType = 14

' Instantiate the client object
Dim Client: Set Client = CreateObject("OpcLabs.EasyOpc.UA.EasyUAClient")

Dim ReadArguments1: Set ReadArguments1 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments1.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments1.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845"
ReadArguments1.AttributeId = UAAttributeId_DataType

Dim ReadArguments2: Set ReadArguments2 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments2.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments2.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853"
ReadArguments2.AttributeId = UAAttributeId_DataType

Dim ReadArguments3: Set ReadArguments3 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments")
ReadArguments3.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
ReadArguments3.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855"
ReadArguments3.AttributeId = UAAttributeId_DataType

Dim arguments(2)
Set arguments(0) = ReadArguments1
Set arguments(1) = ReadArguments2
Set arguments(2) = ReadArguments3

' Obtain values.
Dim results: results = Client.ReadMultipleValues(arguments)

' Display results
Dim i: For i = LBound(results) To UBound(results)
    WScript.Echo

    Dim ValueResult: Set ValueResult = results(i)
    If ValueResult.Succeeded Then
        WScript.Echo "Value: " & ValueResult.Value
        On Error Resume Next
        WScript.Echo "Value.ExpandedText: " & ValueResult.Value.ExpandedText
        WScript.Echo "Value.NamespaceUriString: " & ValueResult.Value.NamespaceUriString
        WScript.Echo "Value.NamespaceIndex: " & ValueResult.Value.NamespaceIndex
        WScript.Echo "Value.NumericIdentifier: " & ValueResult.Value.NumericIdentifier
        On Error Goto 0
    Else
        WScript.Echo "*** Failure: " & ValueResult.ErrorMessageBrief
    End If
Next

' Example output:
'
'Value: SByte
'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=2
'Value.NamespaceUriString: http://opcfoundation.org/UA/
'Value.NamespaceIndex: 0
'Value.NumericIdentifier: 2
'
'Value: Float
'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=10
'Value.NamespaceUriString: http://opcfoundation.org/UA/
'Value.NamespaceIndex: 0
'Value.NumericIdentifier: 10
'
'Value: String
'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=12
'Value.NamespaceUriString: http://opcfoundation.org/UA/
'Value.NamespaceIndex: 0
'Value.NumericIdentifier: 12
REM This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible
REM to read multiple attributes of the same node.
REM
REM Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

Public Sub ReadMultipleValues_DataType_Command_Click()
    OutputText = ""
    
    ' Instantiate the client object
    Dim Client As New EasyUAClient

    Dim readArguments1 As New UAReadArguments
    readArguments1.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    readArguments1.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10845"
    readArguments1.AttributeId = UAAttributeId_DataType

    Dim ReadArguments2 As New UAReadArguments
    ReadArguments2.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    ReadArguments2.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10853"
    ReadArguments2.AttributeId = UAAttributeId_DataType

    Dim ReadArguments3 As New UAReadArguments
    ReadArguments3.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"
    ReadArguments3.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10855"
    ReadArguments3.AttributeId = UAAttributeId_DataType

    Dim arguments(2) As Variant
    Set arguments(0) = readArguments1
    Set arguments(1) = ReadArguments2
    Set arguments(2) = ReadArguments3

    ' Obtain values.
    Dim results() As Variant
    results = Client.ReadMultipleValues(arguments)

    ' Display results
    Dim i: For i = LBound(results) To UBound(results)
        OutputText = OutputText & vbCrLf
        
        Dim Result As valueResult: Set Result = results(i)
        If Result.Succeeded Then
            OutputText = OutputText & "Value: " & Result.value & vbCrLf
            On Error Resume Next
            OutputText = OutputText & "Value.ExpandedText: " & Result.value.expandedText & vbCrLf
            OutputText = OutputText & "Value.NamespaceUriString: " & Result.value.NamespaceUriString & vbCrLf
            OutputText = OutputText & "Value.NamespaceIndex: " & Result.value.NamespaceIndex & vbCrLf
            OutputText = OutputText & "Value.NumericIdentifier: " & Result.value.NumericIdentifier & vbCrLf
            On Error GoTo 0
        Else
            OutputText = OutputText & "*** Failure: " & Result.ErrorMessageBrief & vbCrLf
        End If
    Next

    ' Example output:
    '
    'Value: SByte
    'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=2
    'Value.NamespaceUriString: http://opcfoundation.org/UA/
    'Value.NamespaceIndex: 0
    'Value.NumericIdentifier: 2
    '
    'Value: Float
    'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=10
    'Value.NamespaceUriString: http://opcfoundation.org/UA/
    'Value.NamespaceIndex: 0
    'Value.NumericIdentifier: 10
    '
    'Value: String
    'Value.ExpandedText: nsu=http://opcfoundation.org/UA/ ;i=12
    'Value.NamespaceUriString: http://opcfoundation.org/UA/
    'Value.NamespaceIndex: 0
    'Value.NumericIdentifier: 12
End Sub
Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also