OPC Studio User's Guide and Reference
ReadItemValue(IEasyDAClient,DAReadItemArguments) Method
Example 



View with Navigation Tools
OpcLabs.EasyOpcClassicCore Assembly > OpcLabs.EasyOpc.DataAccess Namespace > IEasyDAClientExtension Class > ReadItemValue Method : ReadItemValue(IEasyDAClient,DAReadItemArguments) Method
The client object that will perform the operation.
Arguments specifying what to read from an OPC-DA server.
Reads a named item from an OPC server. Only the item value is returned (quality and timestamp are not returned). Reads a value of a named item using an object that holds all necessary arguments.
Syntax
'Declaration
 
<ExtensionAttribute()>
<CanBeNullAttribute()>
Public Overloads Shared Function ReadItemValue( _
   ByVal client As IEasyDAClient, _
   ByVal readItemArguments As DAReadItemArguments _
) As Object
 
'Usage
 
Dim client As IEasyDAClient
Dim readItemArguments As DAReadItemArguments
Dim value As Object
 
value = IEasyDAClientExtension.ReadItemValue(client, readItemArguments)

Parameters

client
The client object that will perform the operation.
readItemArguments
Arguments specifying what to read from an OPC-DA server.

Return Value

If successful, the function returns the actual value of OPC item requested.
Exceptions
ExceptionDescription

A null reference (Nothing in Visual Basic) is passed to a method that does not accept it as a valid argument.

This is a usage error, i.e. it will never occur (the exception will not be thrown) in a correctly written program. Your code should not catch this exception.

The OPC "Classic" (or OPC XML-DA) operation has failed. This operation exception in uniformly used to allow common handling of various kinds of errors. The System.Exception.InnerException always contains information about the actual error cause.

This is an operation error that depends on factors external to your program, and thus cannot be always avoided. Your code must handle it appropriately.

Remarks

The server can be local or can be remotely accessed via DCOM. Optionally, an access path can be specified or a specific data type can be requested.

Use this method if you are only interested in the actual value of the OPC item. Use ReadItem method if you also need the quality or timestamp. The ReadItemValue method makes it very easy to obtain the actual data value with just one function call.

The ReadItemValue method waits until the quality becomes "good", or the timeout elapses.

Example

.NET

.NET

// This example shows how to read and display value of a single item.
// One of the shortest examples possible.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

using System;
using OpcLabs.EasyOpc.DataAccess;
using OpcLabs.EasyOpc.OperationModel;

namespace DocExamples.DataAccess._EasyDAClient
{
    partial class ReadItemValue
    {
        public static void Main1()
        {
            // Instantiate the client object.
            var client = new EasyDAClient();

            Console.WriteLine("Reading item value...");
            object value;
            try
            {
                value = client.ReadItemValue("", "OPCLabs.KitServer.2", "Demo.Ramp");
            }
            catch (OpcException opcException)
            {
                Console.WriteLine("*** Failure: {0}", opcException.GetBaseException().Message);
                return;
            }

            Console.WriteLine(value);
        }
    }
}
// This example shows how to read and display value of a single item.
// One of the shortest examples possible.
//
// Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html .

using System;
using OpcLabs.EasyOpc.DataAccess;
using OpcLabs.EasyOpc.OperationModel;

namespace DocExamples.DataAccess.Xml
{
    partial class ReadItemValue
    {
        public static void Main1Xml()
        {
            // Instantiate the client object.
            var client = new EasyDAClient();

            Console.WriteLine("Reading item value...");
            object value;
            try
            {
                value = client.ReadItemValue("http://opcxml.demo-this.com/XmlDaSampleServer/Service.asmx", "Dynamic/Analog Types/Double");
            }
            catch (OpcException opcException)
            {
                Console.WriteLine("*** Failure: {0}", opcException.GetBaseException().Message);
                return;
            }

            Console.WriteLine(value);
        }
    }
}
Requirements

Target Platforms: .NET Framework: Windows 10 (selected versions), Windows 11 (selected versions), Windows Server 2016, Windows Server 2022; .NET: Linux, macOS, Microsoft Windows

See Also