// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible // to read multiple attributes of the same node. // // Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . using System; using OpcLabs.BaseLib.OperationModel; using OpcLabs.EasyOpc.UA; using OpcLabs.EasyOpc.UA.OperationModel; namespace UADocExamples._EasyUAClient { partial class ReadMultipleValues { public static void Main1() { UAEndpointDescriptor endpointDescriptor = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"; // or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported) // or "https://opcua.demo-this.com:51212/UA/SampleServer/" // Instantiate the client object. var client = new EasyUAClient(); // Obtain values. By default, the Value attributes of the nodes will be read. ValueResult[] valueResultArray = client.ReadMultipleValues(new[] { new UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10845"), new UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10853"), new UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10855") }); // Display results. foreach (ValueResult valueResult in valueResultArray) { if (valueResult.Succeeded) Console.WriteLine($"Value: {valueResult.Value}"); else Console.WriteLine($"*** Failure: {valueResult.ErrorMessageBrief}"); } // Example output: // //Value: 8 //Value: -8.06803E+21 //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^ } } }
# This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible # to read multiple attributes of the same node. # # Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . #requires -Version 5.1 using namespace OpcLabs.EasyOpc.UA using namespace OpcLabs.EasyOpc.UA.OperationModel # The path below assumes that the current directory is [ProductDir]/Examples-NET/PowerShell/Windows . Add-Type -Path "../../../Components/Opclabs.QuickOpc/net472/OpcLabs.EasyOpcUA.dll" Add-Type -Path "../../../Components/Opclabs.QuickOpc/net472/OpcLabs.EasyOpcUAComponents.dll" [UAEndpointDescriptor]$endpointDescriptor = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer" # or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported) # or "https://opcua.demo-this.com:51212/UA/SampleServer/" # Instantiate the client object. $client = New-Object EasyUAClient # Obtain values. By default, the Value attributes of the nodes will be read. $valueResultArray = $client.ReadMultipleValues([UAReadArguments[]]@( (New-Object UAReadArguments($endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10845")), (New-Object UAReadArguments($endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10853")), (New-Object UAReadArguments($endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10855")) )) foreach ($valueResult in $valueResultArray) { if ($valueResult.Succeeded) { Write-Host "Value: $($valueResult.Value)" } else { Write-Host "*** Failure: $($valueResult.ErrorMessageBrief)" } } # Example output: # #Value: 8 #Value: -8.06803E+21 #Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
# This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible # to read multiple attributes of the same node. # # Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . # OPC client and subscriber examples in Python on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-Python . # The QuickOPC package is needed. Install it using "pip install opclabs_quickopc". import opclabs_quickopc import time # Import .NET namespaces. from OpcLabs.EasyOpc.UA import * from OpcLabs.EasyOpc.UA.OperationModel import * endpointDescriptor = UAEndpointDescriptor('opc.tcp://opcua.demo-this.com:51210/UA/SampleServer') # or 'http://opcua.demo-this.com:51211/UA/SampleServer' (currently not supported) # or 'https://opcua.demo-this.com:51212/UA/SampleServer/' # Instantiate the client object. client = EasyUAClient() # Obtain values. By default, the Value attributes of the nodes will be read. valueResultArray = IEasyUAClientExtension.ReadMultipleValues(client, [ UAReadArguments(endpointDescriptor, UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10845')), UAReadArguments(endpointDescriptor, UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10853')), UAReadArguments(endpointDescriptor, UANodeDescriptor('nsu=http://test.org/UA/Data/ ;i=10855')), ]) # Display results. for valueResult in valueResultArray: if valueResult.Succeeded: print('Value: ', valueResult.Value, sep='') else: print('*** Failure: ', valueResult.ErrorMessageBrief, sep='') print() print('Finished.')
' This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible ' to read multiple attributes of the same node. ' ' Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . Imports System Imports OpcLabs.BaseLib.OperationModel Imports OpcLabs.EasyOpc.UA Imports OpcLabs.EasyOpc.UA.OperationModel Namespace _EasyUAClient Partial Friend Class ReadMultipleValues Public Shared Sub Main1() ' Define which server we will work with. Dim endpointDescriptor As UAEndpointDescriptor = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer" ' or "http://opcua.demo-this.com:51211/UA/SampleServer" (currently not supported) ' or "https://opcua.demo-this.com:51212/UA/SampleServer/" ' Instantiate the client object Dim client = New EasyUAClient() ' Obtain values. By default, the Value attributes of the nodes will be read. Dim valueResultArray() As ValueResult = client.ReadMultipleValues(New UAReadArguments() _ { New UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10845"), New UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10853"), New UAReadArguments(endpointDescriptor, "nsu=http://test.org/UA/Data/ ;i=10855") } ) ' Display results For Each valueResult As ValueResult In valueResultArray If valueResult.Succeeded Then Console.WriteLine("Value: {0}", valueResult.Value) Else Console.WriteLine("*** Failure: {0}", valueResult.ErrorMessageBrief) End If Next valueResult ' Example output: ' 'Value: 8 'Value: -8.06803E+21 'Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^ End Sub End Class End Namespace
// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible // to read multiple attributes of the same node. // // Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . #include "stdafx.h" // Includes "QuickOpc.h", and other commonly used files #include <atlsafe.h> #include "ReadMultipleValues.h" namespace _EasyUAClient { void ReadMultipleValues::Main() { // Initialize the COM library CoInitializeEx(NULL, COINIT_MULTITHREADED); { // Instantiate the client object _EasyUAClientPtr ClientPtr(__uuidof(EasyUAClient)); _UAReadArgumentsPtr ReadArguments1Ptr(_uuidof(UAReadArguments)); ReadArguments1Ptr->EndpointDescriptor->UrlString = //L"http://opcua.demo-this.com:51211/UA/SampleServer"; L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"; ReadArguments1Ptr->NodeDescriptor->NodeId->ExpandedText = L"nsu=http://test.org/UA/Data/ ;i=10845"; _UAReadArgumentsPtr ReadArguments2Ptr(_uuidof(UAReadArguments)); ReadArguments2Ptr->EndpointDescriptor->UrlString = //L"http://opcua.demo-this.com:51211/UA/SampleServer"; L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"; ReadArguments2Ptr->NodeDescriptor->NodeId->ExpandedText = L"nsu=http://test.org/UA/Data/ ;i=10853"; _UAReadArgumentsPtr ReadArguments3Ptr(_uuidof(UAReadArguments)); ReadArguments3Ptr->EndpointDescriptor->UrlString = //L"http://opcua.demo-this.com:51211/UA/SampleServer"; L"opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"; ReadArguments3Ptr->NodeDescriptor->NodeId->ExpandedText = L"nsu=http://test.org/UA/Data/ ;i=10855"; CComSafeArray<VARIANT> arguments(3); arguments.SetAt(0, _variant_t((IDispatch*)ReadArguments1Ptr)); arguments.SetAt(1, _variant_t((IDispatch*)ReadArguments2Ptr)); arguments.SetAt(2, _variant_t((IDispatch*)ReadArguments3Ptr)); CComVariant vArguments(arguments); // Obtain values. By default, the Value attributes of the nodes will be read. CComSafeArray<VARIANT> results; results.Attach(ClientPtr->ReadMultipleValues(&vArguments)); // Display results for (int i = results.GetLowerBound(); i <= results.GetUpperBound(); i++) { _ValueResultPtr ValueResultPtr = results[i]; _variant_t vString; vString.ChangeType(VT_BSTR, &ValueResultPtr->Value); _tprintf(_T("Value: %s\n"), (LPCTSTR)CW2CT((_bstr_t)vString)); } // Example output: // //Value: 8 //Value: -8.06803E+21 //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^ } // Release all interface pointers BEFORE calling CoUninitialize() CoUninitialize(); } }
// This example shows how to read the Value attributes of 3 different nodes at // once. Using the same method, it is also possible to read multiple attributes // of the same node. // // Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . class procedure ReadMultipleValues.Main; var Client: EasyUAClient; ReadArguments1, ReadArguments2, ReadArguments3: _UAReadArguments; Arguments, Results: OleVariant; I: Cardinal; Result: _ValueResult; begin // Instantiate the client object Client := CoEasyUAClient.Create; ReadArguments1 := CoUAReadArguments.Create; ReadArguments1.EndpointDescriptor.UrlString := //'http://opcua.demo-this.com:51211/UA/SampleServer'; 'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer'; ReadArguments1.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10845'; ReadArguments2 := CoUAReadArguments.Create; ReadArguments2.EndpointDescriptor.UrlString := //'http://opcua.demo-this.com:51211/UA/SampleServer'; 'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer'; ReadArguments2.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10853'; ReadArguments3 := CoUAReadArguments.Create; ReadArguments3.EndpointDescriptor.UrlString := //'http://opcua.demo-this.com:51211/UA/SampleServer'; 'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer'; ReadArguments3.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10855'; Arguments := VarArrayCreate([0, 2], varVariant); Arguments[0] := ReadArguments1; Arguments[1] := ReadArguments2; Arguments[2] := ReadArguments3; // Obtain values. By default, the Value attributes of the nodes will be read. TVarData(Results).VType := varArray or varVariant; TVarData(Results).VArray := PVarArray(Client.ReadMultipleValues( PSafeArray(TVarData(Arguments).VArray))); // Display results for I := VarArrayLowBound(Results, 1) to VarArrayHighBound(Results, 1) do begin Result := IInterface(Results[I]) as _ValueResult; WriteLn('Value: ', Result.Value); end; // Example output: // //Value: 8 //Value: -8.06803E+21 //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^ end;
// This example shows how to read the Value attributes of 3 different nodes at // once. Using the same method, it is also possible to read multiple attributes // of the same node. // // Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . class procedure ReadMultipleValues.Main; var Client: OpcLabs_EasyOpcUA_TLB._EasyUAClient; ReadArguments1, ReadArguments2, ReadArguments3: _UAReadArguments; Arguments, Results: OleVariant; I: Cardinal; Result: _ValueResult; begin // Instantiate the client object Client := CoEasyUAClient.Create; ReadArguments1 := CoUAReadArguments.Create; ReadArguments1.EndpointDescriptor.UrlString := //'http://opcua.demo-this.com:51211/UA/SampleServer'; //'https://opcua.demo-this.com:51212/UA/SampleServer/'; 'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer'; ReadArguments1.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10845'; ReadArguments2 := CoUAReadArguments.Create; ReadArguments2.EndpointDescriptor.UrlString := //'http://opcua.demo-this.com:51211/UA/SampleServer'; //'https://opcua.demo-this.com:51212/UA/SampleServer/'; 'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer'; ReadArguments2.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10853'; ReadArguments3 := CoUAReadArguments.Create; ReadArguments3.EndpointDescriptor.UrlString := //'http://opcua.demo-this.com:51211/UA/SampleServer'; //'https://opcua.demo-this.com:51212/UA/SampleServer/'; 'opc.tcp://opcua.demo-this.com:51210/UA/SampleServer'; ReadArguments3.NodeDescriptor.NodeId.ExpandedText := 'nsu=http://test.org/UA/Data/ ;i=10855'; Arguments := VarArrayCreate([0, 2], varVariant); Arguments[0] := ReadArguments1; Arguments[1] := ReadArguments2; Arguments[2] := ReadArguments3; // Obtain values. By default, the Value attributes of the nodes will be read. TVarData(Results).VType := varArray or varVariant; TVarData(Results).VArray := PVarArray(Client.ReadMultipleValues(Arguments)); // Display results for I := VarArrayLowBound(Results, 1) to VarArrayHighBound(Results, 1) do begin Result := IInterface(Results[I]) as _ValueResult; if Result.Succeeded then WriteLn('Value: ', Result.Value) else WriteLn('results(', I, ') *** Failure: ', Result.ErrorMessageBrief); end; VarClear(Results); VarClear(Arguments); // Example output: // //Value: 8 //Value: -8.06803E+21 //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^ end;
// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible // to read multiple attributes of the same node. // // Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . // Instantiate the client object $Client = new COM("OpcLabs.EasyOpc.UA.EasyUAClient"); $ReadArguments1 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments"); $ReadArguments1->EndpointDescriptor->UrlString = //"http://opcua.demo-this.com:51211/UA/SampleServer"; //"https://opcua.demo-this.com:51212/UA/SampleServer/"; "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"; $ReadArguments1->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845"; $ReadArguments2 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments"); $ReadArguments2->EndpointDescriptor->UrlString = " //"http://opcua.demo-this.com:51211/UA/SampleServer"; //"https://opcua.demo-this.com:51212/UA/SampleServer/"; "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"; $ReadArguments2->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853"; $ReadArguments3 = new COM("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments"); $ReadArguments3->EndpointDescriptor->UrlString = //"http://opcua.demo-this.com:51211/UA/SampleServer"; //"https://opcua.demo-this.com:51212/UA/SampleServer/"; "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer"; $ReadArguments3->NodeDescriptor->NodeId->ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855"; $arguments[0] = $ReadArguments1; $arguments[1] = $ReadArguments2; $arguments[2] = $ReadArguments3; // Obtain values. By default, the Value attributes of the nodes will be read. $results = $Client->ReadMultipleValues($arguments); // Display results for ($i = 0; $i < count($results); $i++) { $ValueResult = $results[$i]; if ($ValueResult->Succeeded) printf("Value: %s\n", $ValueResult->Value); else printf("*** Failure: %s\n", $ValueResult->ErrorMessageBrief); } // Example output: // //Value: 8 //Value: -8.06803E+21 //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
// This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible // to read multiple attributes of the same node. mle_outputtext.Text = "" // Instantiate the client object OLEObject client client = CREATE OLEObject client.ConnectToNewObject("OpcLabs.EasyOpc.UA.EasyUAClient") // Prepare arguments. By default, the Value attributes of the nodes will be read. OLEObject readArguments1 readArguments1 = CREATE OLEObject readArguments1.ConnectToNewObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments") readArguments1.EndpointDescriptor.UrlString = "http://opcua.demo-this.com:51211/UA/SampleServer" readArguments1.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845" OLEObject readArguments2 readArguments2 = CREATE OLEObject readArguments2.ConnectToNewObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments") readArguments2.EndpointDescriptor.UrlString = "http://opcua.demo-this.com:51211/UA/SampleServer" readArguments2.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853" OLEObject readArguments3 readArguments3 = CREATE OLEObject readArguments3.ConnectToNewObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments") readArguments3.EndpointDescriptor.UrlString = "http://opcua.demo-this.com:51211/UA/SampleServer" readArguments3.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855" OLEObject readArgumentsList readArgumentsList = CREATE OLEObject readArgumentsList.ConnectToNewObject("OpcLabs.BaseLib.Collections.ElasticVector") readArgumentsList.Add(readArguments1) readArgumentsList.Add(readArguments2) readArgumentsList.Add(readArguments3) // Obtain values. OLEObject valueResultList valueResultList = client.ReadValueList(readArgumentsList) // Display results Int i FOR i = 0 TO valueResultList.Count - 1 OLEObject valueResult valueResult = valueResultList.Item[i] IF valueResult.Succeeded THEN mle_outputtext.Text = mle_outputtext.Text + "Value: " + String(valueResult.Value) + "~r~n" ELSE mle_outputtext.Text = mle_outputtext.Text + "*** Failure: " + valueResult.ErrorMessageBrief + "~r~n" END IF NEXT // Example output: // //Value: 8 //Value: -8.06803E+21 //Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
REM This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible REM to read multiple attributes of the same node. REM REM Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . Public Sub ReadMultipleValues_Main_Command_Click() OutputText = "" ' Instantiate the client object Dim Client As New EasyUAClient Dim readArguments1 As New UAReadArguments readArguments1.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer" readArguments1.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10845" Dim ReadArguments2 As New UAReadArguments ReadArguments2.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer" ReadArguments2.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10853" Dim ReadArguments3 As New UAReadArguments ReadArguments3.endpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer" ReadArguments3.nodeDescriptor.NodeId.expandedText = "nsu=http://test.org/UA/Data/ ;i=10855" Dim arguments(2) As Variant Set arguments(0) = readArguments1 Set arguments(1) = ReadArguments2 Set arguments(2) = ReadArguments3 ' Obtain values. By default, the Value attributes of the nodes will be read. Dim results() As Variant results = Client.ReadMultipleValues(arguments) ' Display results Dim i: For i = LBound(results) To UBound(results) Dim Result As valueResult: Set Result = results(i) If Result.Succeeded Then OutputText = OutputText & "Value: " & Result.value & vbCrLf Else OutputText = OutputText & "*** Failure: " & Result.ErrorMessageBrief & vbCrLf End If Next ' Example output: ' 'Value: 8 'Value: -8.06803E+21 'Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^ End Sub
Rem This example shows how to read the Value attributes of 3 different nodes at once. Using the same method, it is also possible Rem to read multiple attributes of the same node. Rem Rem Find all latest examples here : https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . Option Explicit ' Instantiate the client object Dim Client: Set Client = CreateObject("OpcLabs.EasyOpc.UA.EasyUAClient") Dim ReadArguments1: Set ReadArguments1 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments") ReadArguments1.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer" ReadArguments1.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10845" Dim ReadArguments2: Set ReadArguments2 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments") ReadArguments2.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer" ReadArguments2.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10853" Dim ReadArguments3: Set ReadArguments3 = CreateObject("OpcLabs.EasyOpc.UA.OperationModel.UAReadArguments") ReadArguments3.EndpointDescriptor.UrlString = "opc.tcp://opcua.demo-this.com:51210/UA/SampleServer" ReadArguments3.NodeDescriptor.NodeId.ExpandedText = "nsu=http://test.org/UA/Data/ ;i=10855" Dim arguments(2) Set arguments(0) = ReadArguments1 Set arguments(1) = ReadArguments2 Set arguments(2) = ReadArguments3 ' Obtain values. By default, the Value attributes of the nodes will be read. Dim results: results = Client.ReadMultipleValues(arguments) ' Display results Dim i: For i = LBound(results) To UBound(results) Dim ValueResult: Set ValueResult = results(i) If ValueResult.Succeeded Then WScript.Echo "Value: " & ValueResult.Value Else WScript.Echo "*** Failure: " & ValueResult.ErrorMessageBrief End If Next ' Example output: ' 'Value: 8 'Value: -8.06803E+21 'Value: Strawberry Pig Banana Snake Mango Purple Grape Monkey Purple? Blueberry Lemon^
Copyright © 2004-2024 CODE Consulting and Development, s.r.o., Plzen. All rights reserved.
Send Documentation Feedback. Technical Support