// This example shows how to obtain acknowledged state of events, and acknowledge an event that is not acknowledged yet. // // Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . using System; using System.Diagnostics; using System.Threading; using OpcLabs.BaseLib.OperationModel; using OpcLabs.EasyOpc.UA; using OpcLabs.EasyOpc.UA.AddressSpace; using OpcLabs.EasyOpc.UA.AddressSpace.Standard; using OpcLabs.EasyOpc.UA.AlarmsAndConditions; using OpcLabs.EasyOpc.UA.Filtering; using OpcLabs.EasyOpc.UA.OperationModel; namespace UADocExamples.AlarmsAndConditions { partial class Acknowledge { public static void AckedState() { // Define which server we will work with. UAEndpointDescriptor endpointDescriptor = "opc.tcp://opcua.demo-this.com:62544/Quickstarts/AlarmConditionServer"; // Instantiate the client objects. var client = new EasyUAClient(); IEasyUAAlarmsAndConditionsClient alarmsAndConditionsClient = client.AsAlarmsAndConditionsClient(); UANodeId nodeId = null; byte[] eventId = null; var anEvent = new ManualResetEvent(initialState: false); // Prepare the Select clauses. UAAttributeFieldCollection selectClauses = UABaseEventObject.AllFields; UASimpleAttributeOperand ackedStateIdOperand = UAFilterElements.SimpleAttribute(UAObjectTypeIds.BaseEventType, "/AckedState/Id"); selectClauses.Add(ackedStateIdOperand); Console.WriteLine("Subscribing..."); client.SubscribeEvent( endpointDescriptor, UAObjectIds.Server, 1000, new UAEventFilterBuilder( // We will auto-acknowledge an event with severity less than 200. UAFilterElements.LessThan(UABaseEventObject.Operands.Severity, 200), selectClauses), (sender, eventArgs) => { if (!eventArgs.Succeeded) { Console.WriteLine($"*** Failure: {eventArgs.ErrorMessageBrief}"); return; } UAEventData eventData = eventArgs.EventData; if (!(eventData is null)) { UABaseEventObject baseEventObject = eventData.BaseEvent; Console.WriteLine(baseEventObject); // Obtain the acknowledge state of the event. ValueResult ackedStateIdResult = eventData.FieldResults[ackedStateIdOperand]; Debug.Assert(!(ackedStateIdResult is null)); if (!ackedStateIdResult.Succeeded) return; bool? ackedStateId = (ackedStateIdResult.Value is bool) ? (bool?)ackedStateIdResult.Value : null; Console.WriteLine($"AckedState/Id: {ackedStateId}"); // Only attempt to acknowledge when not acknowledged yet. if (ackedStateId != false) return; // Make sure we do not catch the event more than once. if (anEvent.WaitOne(0)) return; nodeId = baseEventObject.NodeId; eventId = baseEventObject.EventId; anEvent.Set(); } }, state:null); Console.WriteLine("Waiting for an acknowledgeable event for 10 minutes..."); if (!anEvent.WaitOne(10*60*1000)) { Console.WriteLine("Event not received."); return; } Console.WriteLine(); Console.WriteLine("Acknowledging an event..."); try { alarmsAndConditionsClient.Acknowledge( endpointDescriptor, nodeId, eventId, "Acknowledged by an automated example code."); } catch (UAException uaException) { Console.WriteLine($"*** Failure: {uaException.GetBaseException().Message}"); } Console.WriteLine("Waiting for 5 seconds..."); Thread.Sleep(5 * 1000); Console.WriteLine("Unsubscribing..."); client.UnsubscribeAllMonitoredItems(); Console.WriteLine("Waiting for 5 seconds..."); Thread.Sleep(5 * 1000); Console.WriteLine("Finished."); } } }
# This example shows how to obtain acknowledged state of events, and acknowledge an event that is not acknowledged yet. # # Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . # OPC client and subscriber examples in Python on GitHub: https://github.com/OPCLabs/Examples-QuickOPC-Python . # The QuickOPC package is needed. Install it using "pip install opclabs_quickopc". import opclabs_quickopc import time # Import .NET namespaces. from System.Threading import * from OpcLabs.EasyOpc.UA import * from OpcLabs.EasyOpc.UA.AddressSpace.Standard import * from OpcLabs.EasyOpc.UA.AlarmsAndConditions import * from OpcLabs.EasyOpc.UA.Filtering import * from OpcLabs.EasyOpc.UA.OperationModel import * def eventNotification(sender, eventArgs): global ackedStateIdOperand global anEvent global eventId global nodeId if not eventArgs.Succeeded: print('*** Failure: ', eventArgs.ErrorMessageBrief, sep='') return eventData = eventArgs.EventData if not eventData is None: baseEventObject = eventData.BaseEvent print(baseEventObject) # Obtain the acknowledge state of the event. ackedStateIdResult = eventData.FieldResults.get_Item(UAAttributeField(ackedStateIdOperand)) assert ackedStateIdResult is not None if not ackedStateIdResult.Succeeded: return ackedStateId = ackedStateIdResult.Value print('AckedState/Id: ', ackedStateId, sep='') # Only attempt to acknowledge when not acknowledged yet. if ackedStateId != False: return # Make sure we do not catch the event more than once. if anEvent.WaitOne(0): return nodeId = baseEventObject.NodeId eventId = baseEventObject.EventId anEvent.Set() # Define which server we will work with. endpointDescriptor = UAEndpointDescriptor('opc.tcp://opcua.demo-this.com:62544/Quickstarts/AlarmConditionServer') # Instantiate the client objects. client = EasyUAClient() alarmsAndConditionsClient = IEasyUAClientExtension.AsAlarmsAndConditionsClient(client) nodeId = None eventId = None anEvent = ManualResetEvent(False) # initialState # Prepare the Select clauses. selectClauses = UABaseEventObject.AllFields ackedStateIdOperand = UAFilterElements.SimpleAttribute( UANodeDescriptor(UAObjectTypeIds.BaseEventType), '/AckedState/Id') selectClauses.Add(UAAttributeField(ackedStateIdOperand)) print('Subscribing...') eventFilterBuilder = UAEventFilterBuilder( # We will auto-acknowledge an event with severity less than 200. UAFilterElements.LessThan(UABaseEventObject.Operands.Severity, 200), selectClauses) IEasyUAClientExtension.SubscribeEvent( client, endpointDescriptor, UANodeDescriptor(UAObjectIds.Server), 1000, UAEventFilterBuilder.ToUAEventFilter(eventFilterBuilder), EasyUAEventNotificationEventHandler(eventNotification), None) # state print('Waiting for an acknowledgeable event for 10 minutes...') if not anEvent.WaitOne(10*60*1000): print('Event not received.') exit() print() print('Acknowledging an event...') try: alarmsAndConditionsClient.Acknowledge( endpointDescriptor, UANodeDescriptor(nodeId), eventId, 'Acknowledged by an automated example code.') except UAException as uaException: print('*** Failure: ' + uaException.GetBaseException().Message) print('Event successfully acknowledged.') print() print('Waiting for 5 seconds...') time.sleep(5) print('Unsubscribing...') client.UnsubscribeAllMonitoredItems() print('Waiting for 5 seconds...') time.sleep(5) print('Finished.')
' This example shows how to obtain acknowledged state of events, and acknowledge an event that is not acknowledged yet. ' ' Find all latest examples here: https://opclabs.doc-that.com/files/onlinedocs/OPCLabs-OpcStudio/Latest/examples.html . Imports System Imports System.Threading Imports OpcLabs.BaseLib Imports OpcLabs.BaseLib.OperationModel Imports OpcLabs.EasyOpc.UA Imports OpcLabs.EasyOpc.UA.AddressSpace Imports OpcLabs.EasyOpc.UA.AddressSpace.Standard Imports OpcLabs.EasyOpc.UA.AlarmsAndConditions Imports OpcLabs.EasyOpc.UA.Filtering Imports OpcLabs.EasyOpc.UA.OperationModel Namespace AlarmsAndConditions Partial Friend Class Acknowledge Public Shared Sub AckedState() ' Define which server we will work with. Dim endpointDescriptor As UAEndpointDescriptor = "opc.tcp://opcua.demo-this.com:62544/Quickstarts/AlarmConditionServer" ' Instantiate the client object Dim client = New EasyUAClient() Dim alarmsAndConditionsClient As IEasyUAAlarmsAndConditionsClient = client.AsAlarmsAndConditionsClient() Dim nodeId As UANodeId = Nothing Dim eventId As Byte() = Nothing Dim anEvent = New ManualResetEvent(initialState:=False) ' Prepare the Select clauses. Dim selectClauses As UAAttributeFieldCollection = UABaseEventObject.AllFields Dim ackedStateIdOperand As UASimpleAttributeOperand = UAFilterElements.SimpleAttribute(UAObjectTypeIds.BaseEventType, "/AckedState/Id") selectClauses.Add(ackedStateIdOperand) Console.WriteLine("Subscribing...") client.SubscribeEvent( endpointDescriptor, UAObjectIds.Server, 1000, New UAEventFilterBuilder(UAFilterElements.LessThan(UABaseEventObject.Operands.Severity, 200), selectClauses), ' We will auto-acknowledge an event with severity less than 200. Sub(sender, eventArgs) If Not eventArgs.Succeeded Then Console.WriteLine($"*** Failure: {eventArgs.ErrorMessageBrief}") Return End If Dim eventData As UAEventData = eventArgs.EventData If eventData IsNot Nothing Then Dim baseEventObject = eventArgs.EventData.BaseEvent Console.WriteLine(baseEventObject) ' Obtain the acknowledge state of the event. Dim ackedStateIdResult As ValueResult = eventData.FieldResults(ackedStateIdOperand) Debug.Assert(ackedStateIdResult IsNot Nothing) If Not ackedStateIdResult.Succeeded Then Return End If Dim ackedStateId As Boolean? = If((TypeOf ackedStateIdResult.Value Is Boolean), CType(ackedStateIdResult.Value, Boolean?), Nothing) Console.WriteLine($"AckedState/Id: {ackedStateId}") ' Only attempt to acknowledge when Not acknowledged yet. If Not ackedStateId = False Then Return End If ' Make sure we do not catch the event more than once If anEvent.WaitOne(0) Then Return End If nodeId = baseEventObject.NodeId eventId = baseEventObject.EventId anEvent.Set() End If End Sub, state:=Nothing) Console.WriteLine("Waiting for an acknowledgeable event for 10 minutes...") If Not anEvent.WaitOne(10 * 60 * 1000) Then Console.WriteLine("Event not received") Return End If Console.WriteLine() Console.WriteLine("Acknowledging an event...") Try alarmsAndConditionsClient.Acknowledge( endpointDescriptor, nodeId, eventId, "Acknowledged by an automated example code.") Catch uaException As UAException Console.WriteLine($"*** Failure: {uaException.GetBaseException().Message}") End Try Console.WriteLine("Waiting for 5 seconds...") Thread.Sleep(5 * 1000) Console.WriteLine("Unsubscribing...") client.UnsubscribeAllMonitoredItems() Console.WriteLine("Waiting for 5 seconds...") Thread.Sleep(5 * 1000) Console.WriteLine("Finished.") End Sub End Class End Namespace
Copyright © 2004-2024 CODE Consulting and Development, s.r.o., Plzen. All rights reserved.
Send Documentation Feedback. Technical Support